WCL488

Water Cooled Electronic Loads (Master Unit 12 kW)

Synchronized paralleling creates larger systems controlled as a single unit.

Automated flow regulation to prevent condensation 

Modular design using standard building blocks Low water flow (3gpm @ 10° C / 12 W) 

Self-configuring based on the number of slave load banks in use 

Range switching for increased resolution and accuracy.

Product Specifications

Water Cooled Modules are rated at 12 kW with a selection of voltage and current ratings applicable to the test requirements i.e. 50 V, 100 V, 400 V, and 800 V modules. The master programs itself and the slaves follow. The master and slave modules may be arranged in a rack to create specific systems for the application up to 120 kW/rack. Standard racks are 44” or 60” high x 22” wide x 36” deep. Dimensions given to the right include the rack in the measurements.

The constant resistance mode is popular for power supply regulations, overload and short circuit testing. The constant current mode is popular for circuit breaker and current shunt testing. The constant power mode is often used to test batteries or simulate a constant power load such as a switching regulator.